UNIQUE Fire Suppression Panel
TECHNICAL DATA Model FSP-02 AC Input Voltage 240VAC ± 10%, 50Hz DC Output Voltage 22 – 26VDC Standby Battery 24VDC Rechargeable SLA Type …
45kg Seamless Cylinder with Carbon Dioxide Gas
CO2 cylinder can be connected to a manifold via a non-return valve to enable individual containers to be removed from the system without interruption to the general protection. In general, the cylinders are grouped in rows in any combination.
2-Way Fire Hydrant with Landing Valve
TECHNICAL DATA Part No. HYU-2WHV Working Pressure 15 bar Test Pressure 20 bar Flange Inlet Size (4”) 100mm Table E BS 10 Flange Outlet …
CD Alarm Check Valve
TECHNICAL DATA Part No. SAV-CD-100 (Alarm Valve) SAG-CD (Alarm Gong) SAV-CD-150 (Alarm Valve) SAG-CD (Alarm Gong) Size (mm) 100mm (4”) 150mm (6”) Standard UL …
45L Trolley Type Foam Fire Extinguisher
Foam fire extinguishers cool and extinguish solid material fires and also safely put out fires which involve flammable and combustible liquids. The 45-litre extinguisher is mounted on a trolley and can very quickly be moved from place to place instant use.
25 kg Trolley Type Dry Powder Fire Extinguisher
We assemble 25 kg and 45 kg trolley mounted dry chemical fire extinguishers which are filled with the dry chemical extinguishing agent and compressed nitrogen. They are rated for use against Class A, B, C and E fires.
Room Integrity Test
Enclosure Integrity Test
Now, the NFPA 2001, NFPA 12A, ISO 14520 and EN 15004 recognize an enclosure integrity test as part of the acceptance procedure for all clean agent systems. This includes halocarbon and inert agents. The comprehensive test and calculation procedure predicts how long the agent would stay in the room if it were ever discharged.
The Enclosure Integrity Test’s primary goal is to predict the enclosure’s retention time in the event that the Clean Agent Fire Suppression System is discharged. This is accomplished by performing a Door-Fan test.
What is a Door Fan Test?
Door Fan Test, also known as a Room Integrity Fan Test, is simply a way to measure the leakage of a protected room. A large fan is temporarily installed in the doorway of the protected room to be tested, with the fan blowing into the room (pressurizing the room). The fan speed is adjusted to obtain flow pressure equivalent to the pressure exerted during a fire suppression system discharge. The fan is then reversed on the door to draw air from the room (depressurizing the room). The airflow and pressure readings obtained are entered into a computer program designed to calculate the equivalent leakage area (ELA) for the room. Then, the software will calculate the retention time and determine whether it exceeds the minimum retention time of 10 minutes.
Latching Solenoid
Description
Latching Solenoid is utilized to open a Schrader valve on the top fitting connector of the cylinder valve. The application gives an answer to a quick reaction and a high latching power to be utilized with the UNIQUE Fire Extinguishing Liquid Agent. It was resolved that a latching solenoid with a discretionary nearby manual control head is the best answer for the application.
The actuator is held in the latching position without power until a flag from the operator discharge control board removes the permanent magnet. Whenever discharge, the latching solenoid opens the cylinder valve enabling the quenching medium to release from the cylinder into the system. The latching solenoid is designed with an emergency release local manual control to manually force the pin to depress the cylinder valve to release the extinguishing medium when needed. In order to reset the system, the solenoid is to be manually returned to the latched position. This custom latching solenoid designed specifically for fire protection systems is UL listed and tested in accordance with UL508.
Features
- High latching forces
- Fast response
- Options
- Manual release button cap
- Reset tool
- UL approval-recognized to UL864
- Tested in accordance with UL508
Specification
- Manual actuation force : 12-40lb ƒ (5.44 – 18kgƒ) max
- Operating force : 20.25 – 14.6lbƒ (90 – 65 N) min
- Power requirement : 24 VDC
- Current : 0.5A @ 24 VDC
- Electrical Connection : DIN 43 650-A / ISO 440 3 pin
- Operating Temperature Range : -4 to 131°F (-20 to 55°C)
- Weight : 1.9lbs (.86kg)
- Dimensions
- Body Diameter : 1.61 in (41 mm)
- Length : 4.17 or 5.9 in (106 or 150 mm) with manual actuation cap
Shuttle Valve
TECHNICAL DATA Part No. Description UFI 50123 1” Shuttle Valve UFI 60619 1-1/2” Shuttle Valve
50 kg Trolley Type Dry Powder Fire Extinguisher
We assemble 25 kg and 45 kg trolley mounted dry chemical fire extinguishers which are filled with the dry chemical extinguishing agent and compressed nitrogen. They are rated for use against Class A, B, C and E fires.
Auto Gas Releasing Control Panel
A device that is designed to automatically activate the fire suppression system release sequence when fire is detected.
Standard Features
- Power Source Indicators
- Power Failure Indicators
- Zone Fire, Fault and Isolate Indicators
- Bell Isolate Switch and Indicator
- Gas Isolate Switch and Indicator
- Fault Buzzer Mute Switch
- Master Reset Switch
- Test Lamp Switch
- Test Battery Switch
- Earth Fault Supervisory
- Built-in Delay Discharge Timer (Programmable)
New Features
- GAS Abort Function (Optional)
- Digital Voltmeter and Ammeter
- Intelligent Battery Charger
- Digital Countdown Timer
- Common Fault Contact
- Low Pressure Indicator
Universal Control Head