Shop

Showing 61–72 of 131 results

Views:

Hose Cradle

RM91.00

Hose Cradle

RM91.00

TECHNICAL DATA Part No. WRU-HC Material Mild Steel (Body) Aluminium (Hinge) Support Weight 38 kg max Finishing Red Polyester Electrostatic Powder Coating

Hydrant Hose Cabinet

RM345.00RM350.00

    Hydrant Hose Cabinet

    RM345.00RM350.00

    TECHNICAL DATA Part No. CAB-HCL CAB-HC Model With Legs Without Legs Size (mm) 560(W) x 1170(H ) x 330(D) 560(W) x 600(H) x 330(D) …

      Indoor Fire Extinguisher Cabinet

      RM180.00

      TECHNICAL DATA Model 6kg & 9kg Dry Powder 2kg CO2 Part No. CAB-FEI CAB-FEI Dimension (mm) 280(W) x 240(D) x 710(H) 280(W) x 240(D) …

      Instantaneous Coupling

      RM73.00RM80.00

        Instantaneous Coupling

        RM73.00RM80.00

        TECHNICAL DATA Part No. FHC-F40, FHC-M40 FHC-F65, FHC-M65 Material Light Alloy Inlet Ø40mm Ø65mm Connection Instantaneous

          IRON MAN Water Flow Detector

          RM370.00RM460.00

            IRON MAN Water Flow Detector

            RM370.00RM460.00

            TECHNICAL DATA Part No. SWD-IM-050 SWD-IM-065 SWD-IM-080 SWD-IM-100 SWD-IM-150 SWD-IM-200 Size (mm) 50 65 80 100 150 200 Flow Sensitivity 4 – 10 GPM …

              Kentec Sigma A-CP Conventional Control Panel

              RM0.00

              TECHNICAL DATA Model No. K1810-13 Construction 1.2mm mild sheet steel IP Rating IP30 Finish Epoxy powder coated Colour – lid & box Red RAL …

              Latching Solenoid

              RM1,470.00

              Latching Solenoid

              RM1,470.00

              Description

              Latching Solenoid is utilized to open a Schrader valve on the top fitting connector of the cylinder valve.  The application gives an answer to a quick reaction and a high latching power to be utilized with the UNIQUE Fire Extinguishing Liquid Agent.  It was resolved that a latching solenoid with a discretionary nearby manual control head is the best answer for the application.

              The actuator is held in the latching position without power until a flag from the operator discharge control board removes the permanent magnet.  Whenever discharge, the latching solenoid opens the cylinder valve enabling the quenching medium to release from the cylinder into the system.  The latching solenoid is designed with an emergency release local manual control to manually force the pin to depress the cylinder valve to release the extinguishing medium when needed.  In order to reset the system, the solenoid is to be manually returned to the latched position.  This custom latching solenoid designed specifically for fire protection systems is UL listed and tested in accordance with UL508.

              Features

              • High latching forces
              • Fast response
              • Options
                • Manual release button cap
                • Reset tool
              • UL approval-recognized to UL864
              • Tested in accordance with UL508

               

              Specification

              • Manual actuation force : 12-40lb ƒ (5.44 – 18kgƒ) max
              • Operating force : 20.25 – 14.6lbƒ (90 – 65 N) min
              • Power requirement : 24 VDC
              • Current : 0.5A @ 24 VDC
              • Electrical Connection : DIN 43 650-A / ISO 440 3 pin
              • Operating Temperature Range : -4 to 131°F (-20 to 55°C)
              • Weight : 1.9lbs (.86kg)
              • Dimensions
                • Body Diameter : 1.61 in (41 mm)
                • Length : 4.17 or 5.9 in (106 or 150 mm) with manual actuation cap

              Liquid Level Indicator

              RM1,900.00RM2,130.00

                Liquid Level Indicator

                RM1,900.00RM2,130.00

                Description

                The liquid level indicator is a simple, manually operated device, which provides a means to determine the Clean Agent liquid level in vertically mounted agent storage containers.  Once the liquid level is determined, it can then be converted into the weight of Clean Agent present in the agent storage container.

                Operation

                A magnet equipped float moves with the liquid level along the unit stem.  Level readout is obtained by simply removing the protective cap and pulling out a calibrated tape until magnetic interlock with the float is felt.  With the tape in this position, the reading is obtained at the point where the tape emerges from the unit housing.

                When the liquid level is determined, the reading is then referred to a chart in the Engineering Manual and the corresponding weight of Clean Agent is determined.  Accurate readings can be obtained over a +40°F to +90°F temperature range.

                 Features

                • Reduced maintenance time – weight in an agent storage container can be determined in a fraction of the time it would take to remove and weigh them.
                • Continuous fire protection – use of the liquid level indicator does not require taking out the cylinder from the system, thus providing uninterrupted fire protection.
                • Field installation capability – the indicator can easily be installed in the field using a single wrench as long as the container is empty and is equipped with a mounting boss.
                • Compact – when not in use, the unit requires no more space than that required by the container.
                • Flexibility – the flexible tape design allows the unit to be used in tight spaces that would otherwise hinder the use of a rigid type indicator “stick”.
                • Availability – units are available for all Unique containers from sizes of 150 lb to 1200 lb.

                  Local Manual Control (Plunger Type)

                  RM520.00

                  The Local Manual Control Plunger Type features a local lever driven push rod that depresses a schrader check valve through the latching solenoid when fitted onto the top of the solenoid, thereby venting the pressure from the top of the piston in the cylinder valve, allowing the piston to slide upward and commence cylinder discharge.

                  • Use for manual actuation of cylinder
                  • Equipped with safety pull pin to prevent accidental discharge
                  • Solid brass construction
                  • Stainless steel operation lock-pin

                  Manual Pull Box

                  RM170.00

                  Manual Pull Box

                  RM170.00

                  A device that is designed to activate the fire extinguishing system manually.

                  Outdoor Fire Extinguisher Cabinet

                  RM270.00

                  TECHNICAL DATA Model 9kg Dry Powder 2kg CO2 Part No. CAB-FEO CAB-FEO Dimension (mm) 280(W) x 250(D) x 690(H) 280(W) x 250(D) x 690(H) …

                  PISTON ACTUATOR ASSEMBLY

                  RM470.00

                  Piston Actuator Assembly (P/N: UFI 61041)

                  • High quality brass construction
                  • Mounts directly on top of cylinder valves
                  • Self-venting

                  The Piston Actuator features a pneumatically driven piston that depresses a Schrader check valve, thereby venting the pressure from the top of the piston in the cylinder valve, allowing the piston to slide upward and commence cylinder discharge.  The pneumatic pressure required to operate the Piston Actuator is obtained from the “M” port of a cylinder, which is designated as “Master” cylinder that is either mechanically and/or electrically actuated.  Multiple cylinders equipped with Piston Actuators can be activated from one master cylinder using ¼” copper tubing or ¼” metal flex hose.  The Piston Actuator mounts directly to a top plug adapter, which is located on top of the cylinder valve.