Shop

Showing 73–84 of 131 results

Views:

Plain Sprinkler Rosette

RM3.00RM4.00

    Plain Sprinkler Rosette

    RM3.00RM4.00

    TECHNICAL DATA Part No. SR-CH-15 SR-CH-20 Size (mm) 15mm (½”) 20mm (¾”) Material Stainless Steel 430 Finishing Natural

      PLATON Shunt Orifice Flow Meter

      RM0.00

      [maxbutton id=”1″ url=”https://uniquefire.com/maintenance/wp-content/uploads/2017/05/UFI_catalog-chapter-5_Fire-Sprinkler-System-dragged-1-2.pdf” ]

      Power Line Surge Protector

      RM420.00

      TECHNICAL DATA Model No. 240-5APKD10 Part No. UFI227SP_S.FILTER Location Category Indoor, Boundary LPZ1 – LPZ2 Standard Compliance IEC 61643-1 Class III, AS / NZS …

      Pressure Gauge Guard

      RM160.00

      [et_pb_section fb_built=”1″ _builder_version=”3.22″ background_color=”rgba(255, 255, 255, 0)” custom_padding=”0px||||false|false” global_colors_info=”{}”][et_pb_row _builder_version=”3.25″ background_size=”initial” background_position=”top_left” background_repeat=”repeat” width=”100%” custom_padding=”0px||0px||false|false” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”3.25″ custom_padding=”|||” global_colors_info=”{}” custom_padding__hover=”|||”][et_pb_wc_breadcrumb _builder_version=”3.0.47″ global_colors_info=”{}”][/et_pb_wc_breadcrumb][et_pb_wc_cart_notice _builder_version=”3.0.47″ …

      Pressure Regulating Valve

      RM720.00

      TECHNICAL DATA Part No. WRU-EPRV WRU-EPRV-F Type Screw Type (Thread) Flange Type Size Ø65mm (2 ½”) Test Pressure 30 bar Max. Inlet Pressure 20 …

      Pressure Supervisory Switch

      RM300.00

      TECHNICAL DATA Part No. Description Operation UFI 50138-1 360psi Normally Closed UFI 50138-2 360psi Normally Open

        Pressure Supervisory Switch Guard

        RM160.00

        [et_pb_section fb_built=”1″ _builder_version=”3.22″ background_color=”rgba(255, 255, 255, 0)” custom_padding=”0px||||false|false” global_colors_info=”{}”][et_pb_row _builder_version=”3.25″ background_size=”initial” background_position=”top_left” background_repeat=”repeat” width=”100%” custom_padding=”0px||0px||false|false” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”3.25″ custom_padding=”|||” global_colors_info=”{}” custom_padding__hover=”|||”][et_pb_wc_breadcrumb _builder_version=”3.0.47″ global_colors_info=”{}”][/et_pb_wc_breadcrumb][et_pb_wc_cart_notice _builder_version=”3.0.47″ …

        Pyrocharge with Fitting

        RM370.00

        TECHNICAL DATA Part No. 45KG-PC Material Stainless Steel Body Finishing Natural Voltage 24V

        Range Guard A+ Control Box

        RM1,110.00

        TECHNICAL DATA Part No. Model No. Size (mm) Operating Temperature Range Actuation Mode Number of Extinguishing System Cylinders Maximum Total Length Copper Actuation Tubing …

        Room Integrity Test

        RM1,470.00

        Room Integrity Test

        RM1,470.00

        Enclosure Integrity Test

        Now, the NFPA 2001, NFPA 12A, ISO 14520 and EN 15004 recognize an enclosure integrity test as part of the acceptance procedure for all clean agent systems.  This includes halocarbon and inert agents.  The comprehensive test and calculation procedure predicts how long the agent would stay in the room if it were ever discharged.

        The Enclosure Integrity Test’s primary goal is to predict the enclosure’s retention time in the event that the Clean Agent Fire Suppression System is discharged.  This is accomplished by performing a Door-Fan test.

        What is a Door Fan Test?

        Door Fan Test, also known as a Room Integrity Fan Test, is simply a way to measure the leakage of a protected room.  A large fan is temporarily installed in the doorway of the protected room to be tested, with the fan blowing into the room (pressurizing the room).  The fan speed is adjusted to obtain flow pressure equivalent to the pressure exerted during a fire suppression system discharge.  The fan is then reversed on the door to draw air from the room (depressurizing the room).  The airflow and pressure readings obtained are entered into a computer program designed to calculate the equivalent leakage area (ELA) for the room.  Then, the software will calculate the retention time and determine whether it exceeds the minimum retention time of 10 minutes.

        Shuttle Valve

        RM1,620.00RM2,390.00

          Shuttle Valve

          RM1,620.00RM2,390.00

          TECHNICAL DATA Part No. Description UFI 50123 1” Shuttle Valve UFI 60619 1-1/2” Shuttle Valve